现货大促销,价格低至8折起,量大更优惠,详细咨询客服
全部分类
全部分类
  • (±)19(20)-EpDPA MaxSpec® Standard
(±)19(20)-EpDPA MaxSpec® Standard的可视化放大

(±)19(20)-EpDPA MaxSpec® Standard

原价
¥3142-3142
价格
2514-2514
(±)19(20)-EpDPA MaxSpec® Standard的二维码

所有产品仅用于科学研究,我们不为任何个人用途提供产品和服务

询价有惊喜,量大更优惠 点击这里给我发消息

可选包装 >>>
首页
EDHF (endothelium-derived hyperpolarizing factor) is an unidentified mediator released from vascular endothelial cells in response to acetylcholine and bradykinin which is distinct from the NOS- (nitric oxide) and COX-derived (prostacyclin) vasodilators.

货号:ajcx17676
CAS:N/A
分子式:C22H32O3
分子量:344.5
溶解度:Soluble in DMSO
纯度:98%
存储:Store at -20°C
库存:现货

Background:

EDHF (endothelium-derived hyperpolarizing factor) is an unidentified mediator released from vascular endothelial cells in response to acetylcholine and bradykinin which is distinct from the NOS- (nitric oxide) and COX-derived (prostacyclin) vasodilators. Cytochrome P450 (CYP450) metabolism of polyunsaturated fatty acids produces epoxides such as (±)14(15)-EpETrE which are prime candidates for the actual active mediator. However, the CYP450 metabolites of eicosapentaenoic acid and docosahexaenoic acid have been little studied relative to arachidonate epoxygenase metabolites. (±)19(20)-EpDPA is a DHA epoxygenase metabolite, derived via epoxidation of the ω-3 double bond of DHA. The EDHF activity of (±)19(20)-EpDPA has not yet been determined. The epoxygenase metabolites of DHA have also been detected in a mouse inflammation model. (±)19(20)-EpDPA MaxSpec® standard is a quantitative grade standard of (±)19(20)-EpDPA that has been prepared specifically for mass spectrometry and related applications where quantitative reproducibility is required. The solution has been prepared gravimetrically and is supplied in a deactivated glass ampule sealed under argon. The concentration was verified by comparison to an independently prepared calibration standard. This (±)19(20)-EpDPA MaxSpec® standard is guaranteed to meet identity, purity, stability, and concentration specifications and is provided with a batch-specific certificate of analysis. Ongoing stability testing is performed to ensure the concentration remains accurate throughout the shelf life of the product. Note: The amount of solution added to the vial is in excess of the listed amount. Therefore, it is necessary to accurately measure volumes for preparation of calibration standards. Follow recommended storage and handling conditions to maintain product quality.

动态评分

0.0

没有评分数据
没有评价数据
一键回到顶部
展开 收缩
安捷凯在线客服